+86 021 67109909     +86 18017809222
All Categories

Home > Products > Load Break Switch > 24KV indoor load break switch

  • Indoor High Voltage Load Break Switch And Fuse Combination Apparatus
  • Indoor High Voltage Load Break Switch And Fuse Combination Apparatus

Indoor High Voltage Load Break Switch And Fuse Combination Apparatus

Description:

FKRN24D when load break switch equip with high voltage current limited fuse(with striker), it comes into being load break switch and fuse combination apparatus,acting as protecting and control apparatus for transformers,cable and overhead wiring. When a phase or multiphase fuse fusing, load break switch automatic brake three-phase.
These series load break switch are especially applicable in rural,urban terminal substation and prefabricated substations, as well as ring network power supply.

  • Product Description

Indoor High Voltage Load Break Switch and Fuse Combination Apparatus

General Description:

FKRN24D when load break switch equip with high voltage current limited fuse(with striker), it comes into being load break switch and fuse combination apparatus,acting as protecting and control apparatus for transformers,cable and overhead wiring. When a phase or multiphase fuse fusing, load break switch automatic brake three-phase.
These series load break switch are especially applicable in rural,urban terminal substation and prefabricated substations, as well as ring network power supply.

Ambinent Condition:

Ambinent condition

Standard:

1) GB3804-2004 ((3-63KV AC high voltage load break switch))
2) GB16926-2009 ((AC high voltage load break switch-fuse combination apparatus)
Normal Working Condition:
Altitude: no more than 1000m;
Ambient temperature: -10℃一+40℃;
Relative humidity: daily average no more than 95%, monthly average no more than 90%;
Earthquake degree: less than 8℃;

Technical Specification:

The technical specification of load break switch (including earthing switch), see form 1. Mechanical performance of load break switch,see form 2. Mechanical performance of earthing switch,see form 3.

Form 1: the technical specification of load break switch (including earthing switch)

Form 1: the technical specification of load break switch (including earthing switch)

Form 2: mechanical performance of load break switch

Form 2: mechanical performance of load break switch

Form 3: mechanical performance of earthing switch

Form 3: mechanical performance of earthing switch

FKRN24D side-mounted right operation, upside down side-mounted left operation

FKRN24D side-mounted left operation, upside down side-mounted right operation

Trepanning size of panel

Outline and installation dimensions

Electrical principle diagram

 

 