+86 021 67109909     +86 18017809222
All Categories

Home > Products > Embedded Pole

  • Solid Seal Pole Column EEP-122000-40
  • Solid Seal Pole Column EEP-122000-40

Solid Seal Pole Column EEP-122000-40

Description:

solid seal pole column,or called vacuum interrupter with epoxy resin,is made by casting vacuum interrupters,main circuit conduct and mounting parts with epoxy into an integral part.

  • Product Description

Model No: EEP-12/2000-40

Solid seal pole column has the following advantages

1.the traditional packaged very column, compared to solid seal pole column part number a large number of reducing, conductor lap surface by six group reduced to 3 groups, connecting bolt by eight reduced to 1 ~ 3, (see chart 7) simple structure greatly improved the reliability of the circuit breaker

2.Due to the vacuum arc extinguish chamber was embedded into solid material, so don’t need to do any further processing, solid seal pole column can achieve a high dielectric strength; Vacuum arcing chamber was embedded into solid materials, extremely column external environment on vacuum arcing chamber’s influence was reduced to the least

Parameters of solid seal pole column

MAIN TECHNICAL SPECIFICATION UNIT SPECIFICATION
2000
Rated voltage kV 12
Rated current A 2000
Rated frequency Hz 50/60
Short-duration(1min) power frequency withstand voltage  kV 48
Lightning impulse withstand voltage kV 95
Rated short-circuit breaking current kA 40
Rated peak withstand current kA 100
Rated short-circuit making current kA 100
Rated short-time withstand current kA 40
Rated duration of short-circuit S 4
Rated breaking current of single capacitor bank A 400
Rated breaking current of back to back capacitor bank A 400
Rated operating sequence o-0.3S-co180S-co
Breaking operations of rated short circuit breaking current Time 30
Mechanical endurance Time 20000
Contact self-close force N 120±50 
Force required to hold contacts open at full stroke N 200±50 
Circuit resistance at lower limit of rated contact force mΩ  ≤ 20 
Contact limit erosion mm 3
Gas pressure inside vacuum interrupter Pa ≤ 1X10-3 
Partial discharge Pc ≤ 5 
Weight of moving parts Kg
Weight of vacuum interrupter embedded poles Kg

Mechanical data required for the matched vacuum switchgear

MAIN TECHNICAL SPECIFICATION UNIT SPECIFICATION
2000
Clearance between open contacts mm 10±1 
Average opening speed m/s 1.05±0.15 
Average closing speed m/s 0.7±0.2 
Rated contact pressure N 5000±200 
Contact bouncing duration at closing operation ms ≤ 3 
Out of simultaneity of contact closing and opening ms ≤ 2 
Bouncing back amplitude of opening contact mm ≤ 3 

drawing Solid seal pole column EEP-12/2000-40

Information for solid seal pole column 
From the development of insulations on breakers,it can be divided into three generations:air, composite and solid insulation and so-called solid insulation means solid seal pole column,which might represent the great advancement of insulation on vacuum breakers.Since the epoxy can be used to replace the insulating and mechanical supports,the breakers therefore become compact and simple and are able to service under humid and dusty conditions.When the external insulations of miniature chambers in air condition fail to fulfill the requests of specifications,solid seal pole column are therefore introduced and now become one of the most applicable ways in the field of medium voltage breakers either at home or abroad.

Contact Us